Suggested Maintenance
Maintenance to be performed daily:
⯁ Pickup debris and empty trash receptacles
⯁ Wash down bay(s)
⯁ Test each bay meter by inserting coin, token, credit card and/or bill (applicable items) to insure acceptance and smooth operation
⯁ Initiate bay cycle, verify proper pressure, inspect for leaks and operation
⯁ Activate vacuums, test suction, inspect hose(s) and attachment(s)
⯁ Operate bill changer, check bill acceptance and proper change
⯁ Test vendors for coin/bill acceptance and activation
⯁ Examine oil level and condition for pumps
⯁ Examine oil level and condition for air compressor
⯁ Check chemical levels
Maintenance to be performed weekly:
⯁ Maintain landscaping and/or lawn
⯁ Empty vacuum debris bins and clean dust filters
⯁ Sweep or wash-down all paved surfaces
⯁ Measure residue level in sediment traps
⯁ Drain condensed water from air compressor tank (if applicable)
⯁ Check 24 hour timers for lighting and water softener regeneration
⯁ Refill water softener brine reservoir
⯁ Restock vendors
Maintenance to be performed monthly:
⯁ Lubricate locks with graphite
⯁ Adjust light timer settings
⯁ Replace pre-filter(s) for reverse osmosis system
⯁ Lubricate pump seals (if applicable)
⯁ Inspect pump drive belts for wear and adjust tension
Maintenance to be performed at 500 hours of operation:
⯁ Change high-pressure pump and air compressor oil
⯁ Replace vacuum dust filter bags
⯁ Replace activated carbon media for reverse osmosis system
Maintenance to be performed annually:
⯁ Clean walls and parking lot with pressure washer
⯁ Paint exposed building metal
Required maintenance to be performed as needed:
⯁ Inspect hoses, trigger guns, nozzles and brushes for wear
⯁ Repair all leaks
⯁ Replace pump seals and/of valves at the first indication of pulsation, leaks or wear
⯁ Clean or replace reverse osmosis membrane when reduction of permeate is evident
⯁ Remove graffiti, dated signs or deteriorated banners
⯁ Replace worn or frayed bay and/or vacuum components
⯁ Replace faded or torn/cut decals
⯁ Clean-out sediment traps before clogging occurs